Pulse Pro Basic Setup

Lock in factory mode (unlocks when “1” is pressed)

1. Set lock configuration and date format: *Lock bolt must remain in the retracted position throughout the configuration setup procedure*

  • Determine configuration # from the list below (Fig 1A) or refer to the configuration chart in the full instructions for all options
  • Retract the lock bolt
  • Press & hold “8” until lock double signals & red LED remains on
  • Enter configuration ID
  • Reenter configuration ID
  • Enter date format (0=Day/Month/Year, 1=Month/Day/Year)
  • LED flashes, keypad emits 2 beeps, LED goes out
  • Lock will now be in operating mode, preset Manager & Master codes are active
  • Manager: 60-123456 (Opens lock)
  • Master: 80-123456 (Does NOT open lock)
  • *If a dual custody configuration was set, a user must be activated before the lock can be opened*

Fig. 1A – Common configuration IDs:

  • 12: 10 users, single custody, manager management
  • 17: 50 users, single custody, manager management
  • 13: 10 users, dual custody, manager management, 1 TD override user (10)
  • 18: 50 users, dual custody, manager management, 10 TD override users (50 – 59)

2A. Activate Users: (Single Custody Mode)

  • Press & hold “1” until the lock double signals & the red LED remains on
  • Enter manager code, including position (60)
  • Enter user position to be added (2 digits)
  • Enter new user code
  • Reenter the new user code

2B. Activate Users: (Dual Custody Mode)

  • Press & hold “1” until the lock double signals & the red LED remains on
  • Enter manager code, including position (60)
  • Enter Master code, including position (80)
    • Any user code can be used in place of the master code once activated
  • Enter user position to be added (2 digits)
  • Enter new user code
  • Reenter the new user code

3. Set Time Delay: (Optional)

  • Press & hold “9” until lock double signals & red LED remains on
  • Enter manager code, including position (60)
  • Enter time delay (XX) followed by open window(XX)
  • Reenter time delay (XX) followed by open window(XX)

Ghi chú:

  • Push / Pull-rated motorized deadbolts are set to manual extension by default
    • Press the “P” button to extend the bolt
  • Manager & Master codes are changed using the “Change User Code” instructions below
  • Detailed instructions, including all available configuration options, may be found in the full version of “Pulse Pro User Instructions” (QR link below)

LOCKMASTERS Pulse Pro Basic Setup - QR Codehttps://www.tecnosicurezza.it/admin/workspace/doc-ing/iu_pulsepro_12_eng.pdf

Changing User Code
*It is strongly recommended that code changes be performed with the door open*

  1. Press & hold “0” until lock double signals & red LED remains on
  2. Enter user position to be changed (1st 2 digits)
  3. Enter existing user code (6 digits)
  4. Enter new user code (6 digits)
  5. Reenter new user code (6 digits)

*Test new code at least 3X before closing door*

Để được hỗ trợ thêm, vui lòng gọi 800-654-0637LOCKMASTERS logo

Tài liệu / Tài nguyên

LOCKMASTERS Pulse Pro Basic Setup [tập tin pdf] Hướng dẫn sử dụng
PULSEPRO-SETUP-INST, Pulse Pro Basic Setup, Pro Basic Setup, Basic Setup

Tài liệu tham khảo

Để lại bình luận

Địa chỉ email của bạn sẽ không được công bố. Các trường bắt buộc được đánh dấu *