1. Giới thiệu
This manual provides detailed instructions for the safe and efficient operation of your Albott 9000 BTU Mini Split Air Conditioner Heat Pump. This inverter ductless AC system offers cooling, heating, dehumidifying, and fan modes, designed for spaces up to 450 sq. ft. It features energy-efficient operation with an 18.5 SEER2 rating and includes a self-cleaning function for easy maintenance.

Figure 1: Albott 9000 BTU Mini Split Air Conditioner Heat Pump and included accessories.
2. Thông tin an toàn quan trọng
WARNING: Risk of Fire. Flammable Refrigerant Used. To Be Repaired ONLY By Trained Service Personnel. Do Not Puncture Refrigerant Tubing. Dispose Of Properly In Accordance With Federal Or Local Regulations.
- Installation and servicing of this equipment should only be performed by qualified, licensed HVAC technicians.
- Đảm bảo nối đất thích hợp để tránh bị điện giật.
- Do not install or operate the air conditioner until the power is off for at least five minutes.
- Giữ khu vực xung quanh thiết bị ngoài trời không có vật cản để đảm bảo luồng không khí lưu thông tốt.
- Avoid installing near heat sources, steam sources, or areas with flammable/explosive gases.
3. Có gì trong hộp
Your Albott Mini Split Air Conditioner package includes the following components:
- Đơn vị trong nhà
- Đơn vị ngoài trời
- Hướng dẫn sử dụng
- Điều khiển từ xa
- Batteries (Alkaline)
- Hanging plate for the indoor unit
- Drain pipe for the indoor unit
- Installation dimension drawing template
- 14.76 Ft communication wires
- Tay áo tường
- Bột trét
- Copper connection pipe - air pipe
- Copper connection pipe - liquid pipe
- 8.2 Ft power cord
- Băng dính

Figure 2: All components included in the Albott Mini Split Air Conditioner package.
4. Thiết lập và Cài đặt
Proper installation is crucial for optimal performance and safety. It is recommended that installation be performed by a licensed professional.
4.1 Kiểm tra trước khi cài đặt
- Ensure the installation location for the indoor unit is hard, flat, and firm to avoid vibration and noise.
- Maintain adequate clearance around both indoor and outdoor units for proper airflow. Refer to the dimension drawing for specific clearances.
- Avoid installing near heat sources, steam sources, or in areas with smoke, oil, flammable, or corrosive gases.

Figure 3: Recommended clearances for indoor unit installation.
4.2 Lắp đặt dàn lạnh
- Remove the mounting bracket from the back of the indoor unit.
- Use the provided paper pattern/template to identify the exact location for drilling holes for the mounting bracket and piping.
- Drill screw holes in the corresponding positions and insert expansion tubes.
- Securely mount the bracket on the wall using expansion screws.
- Drill a wall hole for the refrigerant pipes, ensuring it is inclined outward by 5-10 degrees with a diameter of 60-80mm. Use an anti-dust bag to collect debris.
- Confirm the direction for placing the air conditioning ducts and remove the knock-out panel with a knife, removing any burrs to prevent damage to the drain pipe.
- Pass the communication cable through the hole on the back of the indoor unit and connect the wires to the terminal board according to the color-coded wiring diagram. Secure the wires with the fixing plate.
- Connect the drain hose to the water outlet pipe, ensuring a tight fit.
- Line up all wires and pipes neatly, wrap them together with plastic tapes, and pass them through the wall hole.
- Hang the indoor unit on the mounting plate, ensuring it clicks firmly into place.
- Use pipe protection rings and putty to seal the wall hole around the pipes.
Video 1: Detailed installation guide for the split air conditioner, including indoor unit setup and wiring.
4.3 Lắp đặt dàn nóng
- Place the outdoor unit in a suitable location, either on a wall bracket (purchased separately) or directly on the ground. Ensure the location is firm and flat to prevent vibration and noise.
- Maintain adequate clearance around the outdoor unit. Refer to the dimension drawing for specific clearances.
- Connect the two refrigerant pipes (gas and liquid) to the outdoor unit, ensuring the joints fit snugly and are tightened with a wrench.
- Remove the electrical box cover by unscrewing the three screws.
- Pass the power cable wires through the cover hole (usually the right-hand hole) and fix the wires to the terminal board according to the wiring diagram. Secure the fixing plate.
Video 2: Detailed installation guide for the split air conditioner, including outdoor unit setup and wiring.
4.4 Vacuuming and Refrigerant Release
- Connect the stop valve, charging hose, manifold valve, and vacuum pump as shown in the diagram.
- Vacuumize the system for at least 15 minutes, ensuring the pressure gauge value is ≤ -0.1MPa (-76cmHg / 500µm).
- Maintain the pressure for 3-5 minutes after vacuumizing. The pressure springback should be ≤ 0.05MPa.
- Open the 1/4 liquid valve and remove the charging hose.
- Using an Allen wrench, open all the liquid valves and gas valves. Finally, retighten the three caps.
Video 3: Detailed installation guide for the split air conditioner, including vacuuming and refrigerant release.
5. Hướng dẫn vận hành
Your Albott Mini Split system offers multiple modes and features for optimal comfort control.
5.1 Chức năng điều khiển từ xa
The remote control allows you to adjust settings from up to 30 feet away. It features buttons for mode selection, temperature adjustment, fan speed, and special functions.

Figure 4: Remote control for Albott Mini Split Air Conditioner.
5.2 Chế độ hoạt động
- Chế độ làm mát: Provides efficient cooling to maintain desired room temperature.
- Chế độ sưởi ấm: Functions as a heat pump to warm your space.
- Chế độ hút ẩm: Reduces humidity levels in the air.
- Chế độ quạt: Lưu thông không khí mà không cần làm mát hoặc sưởi ấm.
- Chế độ tự động: Automatically selects the appropriate mode based on the set temperature and ambient conditions.
- Chế độ ngủ: Adjusts temperature and fan speed for comfortable sleep while conserving energy.
- Chế độ tiết kiệm: Optimizes energy consumption for cost savings.

Figure 5: The 4-in-1 functionality of the Albott Mini Split system.
5.3 Điều chỉnh nhiệt độ và tốc độ quạt
- Adjust temperature settings between 60°F and 90°F using the remote control.
- Select from Low, Mid, High, or Turbo fan speeds to control airflow intensity.
- Utilize the 4-way swing function for personalized airflow direction.

Figure 6: 4D Adjustable Airflow for optimal comfort.
6. Bảo trì
Regular maintenance ensures the longevity and efficiency of your unit.
6.1 Chức năng tự làm sạch
The unit features a 135°F self-cleaning function to help remove dust buildup. A reminder will appear every 500 hours of operation to activate the 30-minute self-cleaning cycle.

Figure 7: Self-cleaning technology for hassle-free maintenance.
6.2 Bộ lọc bụi có thể tháo rời
The detachable dust filter can be easily removed for quick and hassle-free cleaning. Regular cleaning of the filter helps trap dust and particles, ensuring fresher air circulation and enhanced durability of internal components.

Hình 8: Bộ lọc bụi có thể tháo rời để dễ dàng vệ sinh.
7. Thông số kỹ thuật
| Tính năng | Chi tiết |
|---|---|
| Thương hiệu | Albott |
| Thông tin mô hình | SAC011 |
| Công suất làm mát | 9000 Đơn vị nhiệt Anh |
| Công suất sưởi ấm | 9200 BTU |
| Khu vực phủ sóng | Lên tới 450 feet vuông |
| Tỷ lệ hiệu quả năng lượng theo mùa (SEER2) | 18.5 |
| Tậptage | 220 vôn |
| Cái gì?tage | 800 watt |
| Mức độ tiếng ồn | 29 Decibel |
| Kích thước sản phẩm | 29.92"D x 11.61"W x 7.9"H |
| Tính năng đặc biệt | 4 Way Swing, Auto Clean, Dust Filter, Fast Cooling, Heating & Cooling Function |

Hình 9: Kích thước sản phẩm và thông số kỹ thuật.
8. Bảo hành và Hỗ trợ
For any product inquiries, technical support, or warranty claims, please contact Albott customer service. A customer review mentioned that Albott provides prompt responses and resolutions. You can reach them at: support@albott-us.com.