The ITECH IT6720 is a high-performance digital-control variable DC power supply designed for a wide range of applications, from laboratory research to production line testing. It provides stable and precise voltage and current output with automatic constant current (CC) and constant voltage (CV) conversion modes. Equipped with multiple protection functions, this power supply ensures safe and reliable operation.

ITECH IT6720 Variable DC Power Supply front view

Hình 1: Mặt trước view of the ITECH IT6720 Variable DC Power Supply.

Sản phẩm trênview

Bố cục bảng điều khiển phía trước

Front panel with labeled components

Hình 2: Chi tiết view of the front panel, showing the CC/CV indicators, OCP/OVP indicators, memory save buttons, keyboard lock, voltage/current adjust knob, output ON/OFF button, and display switch button.

Bố cục bảng điều khiển phía sau

Rear panel with labeled components

Hình 3: Chi tiết view of the rear panel, indicating the power switch, AC power input, 9-pin connector (for factory use only), and cooling fan.

Cài đặt

  1. Kết nối nguồn điện: Connect the supplied power cord to the AC power input on the rear panel (Figure 3). Ensure the power switch is in the OFF position before connecting.
  2. Tậptage Lựa chọn: Xác minh voltage selector switch on the rear panel is set to the correct local AC voltage (110V or 220V). Adjust if necessary using a small flat-head screwdriver.
  3. Kết nối đầu ra: Connect your load to the output terminals on the front panel. The red terminal is positive (+), the black terminal is negative (-), and the green terminal is ground. Ensure secure connections.
  4. Bật nguồn ban đầu: Flip the power switch on the rear panel to the ON position. The display on the front panel should illuminate.

Video 1: A brief demonstration of the ITECH IT6700 series DC power supply, including power-on and basic operation.

Hướng dẫn sử dụng

  1. Đặt Voltage và Hiện tại: Use the large rotary knob to adjust the voltage and current values. Press the 'Shift' button to toggle between coarse and fine adjustment modes for precise control. The display will show the set values.
  2. Bật/Tắt đầu ra: Press the 'On/off' button to enable or disable the output. The display will indicate if the output is active.
  3. CC/CV Automatic Conversion: Bộ nguồn tự động chuyển đổi giữa điện áp không đổi.tage (CV) and Constant Current (CC) modes depending on the load. The corresponding indicator (CC or CV) on the display will light up.
  4. Chức năng bảo vệ: The unit is equipped with Over Current Protection (OCP), Over Voltage Protection (OVP), and Over Temperature Protection (OTP). If any of these conditions are met, the output will shut down and the respective indicator will light up.
  5. Chức năng bộ nhớ: Use the 'Save' and 'Prog' buttons (A, B, C, D) to store and recall frequently used voltage and current settings. Refer to the detailed manual for specific programming steps.
  6. Khóa bàn phím: The 'Lock' button can be used to prevent accidental changes to settings during operation.

Video 2: Một kết thúcview of the IT6700 DC Power Supply's features, including its bright display, high resolution, and CV/CC modes.

Key lock feature on power supply

Figure 4: The key lock feature helps prevent accidental changes to settings.

Adjust step value settings for voltage và hiện tại

Figure 5: Table illustrating the different adjustment step values for voltage and current (e.g., 1V, 0.1V, 0.01V for voltage; 1A, 0.1A, 0.01A, 0.001A for current).

BẢO TRÌ

Thay thế cầu chì

The ITECH IT6720 power supply is equipped with a replaceable fuse for protection against overcurrent. If the unit fails to power on or experiences unexpected shutdowns, the fuse may need replacement. The fuse holder is located on the rear panel, near the AC power input.

  1. Ngắt nguồn: Ensure the power supply is completely disconnected from the AC mains before attempting any maintenance.
  2. Locate Fuse Holder: Identify the fuse holder on the rear panel (refer to Figure 3). It is typically a small, cylindrical cap that can be twisted or pulled out.
  3. Tháo cầu chì cũ: Use a small flat-head screwdriver or your fingernail to gently pry open or twist the fuse holder cap. Carefully remove the old fuse.
  4. Check Fuse Rating: The required fuse rating is printed on the rear panel near the fuse holder. For 110V AC operation, the fuse is typically 3.15A/250V. For 220V AC operation, it is 1.5A/250V. Always replace with a fuse of the exact same type and rating.
  5. Lắp cầu chì mới: Place the new fuse into the fuse holder cap and reinsert it into the power supply, ensuring it is securely seated.
  6. Kết nối lại nguồn điện: Reconnect the power supply to the AC mains and test its operation.

Note: If the fuse blows repeatedly, there may be an underlying issue with the unit or your electrical setup. Contact technical support for assistance.

Thông số kỹ thuật

Đặc điểm kỹ thuậtGiá trị
Đầu ra Voltage0-60V
Dòng điện đầu ra0-5A
Quyền lực0-100W
Tậptage Độ phân giải0.01V
Độ phân giải hiện tại0.001A
Tậptage Độ chính xác<0.05% + 10mV
Độ chính xác hiện tại<0.1% + 2mA
Kích thước sản phẩm (D x R x C)11.1 x 6.9 x 3.5 inch
Trọng lượng sản phẩm7.7 pound
Phương pháp làm mátKhông khí

For a complete list of specifications, please refer to the official product documentation.

Dimensions of the ITECH IT6720 power supply

Figure 6: Product dimensions of the ITECH IT6720.

Power curve graph for ITECH IT6720

Figure 7: Power curve illustrating the voltage and current capabilities within the rated power.

Xử lý sự cố

  • Thiết bị không bật nguồn:
    1. Check if the power cord is securely connected to both the unit and the AC outlet.
    2. Verify the power switch on the rear panel is in the ON position.
    3. Inspect the fuse on the rear panel. If blown, replace it with a fuse of the correct rating (refer to Maintenance section).
  • Không có vol đầu ratage / hiện tại:
    1. Ensure the output ON/OFF button on the front panel is enabled.
    2. Check if any protection indicators (OCP, OVP, OTP) are lit. If so, resolve the overload/overvoltage/overtemperature condition and reset the unit.
    3. Xác minh rằng voltage and current settings are not set to zero.
  • Difficulty with user interface/modes:
    The IT6720 uses a single control knob with multiple modes. Refer to the detailed user manual (PDF link provided in product documents) for a comprehensive explanation of each mode (Mode A, B, C, D) and how to navigate them using the 'Shift' and 'Setup' buttons. Practice adjusting values in different modes to become familiar with the interface.

Bảo hành và Hỗ trợ

ITECH provides professional technical support for its products both before and after sale. For any technical inquiries, operational assistance, or warranty claims, please contact ITECH customer service directly.

Refer to the official ITECH website or the documentation included with your product for the most up-to-date contact information and warranty details.

Contact Technical Team email address

Figure 8: Contact information for ITECH Technical Team.