Apera Instruments AI1107

Apera Instruments 3M KCL Storage Soaking Solution

Mẫu: AI1107

Brand: Apera Instruments

Sản phẩm trênview

The Apera Instruments 3M KCL Storage Solution is specifically formulated with high-purity chemicals to maintain and extend the operational lifespan of pH and ORP electrodes. This solution is essential for proper electrode care, preventing sensitivity and accuracy degradation that can occur when electrodes are stored dry.

Các tính năng chính bao gồm:

Thiết lập và Chuẩn bị

Before storing your pH or ORP electrode, ensure it is thoroughly cleaned according to your electrode's specific cleaning instructions. This removes any contaminants that could affect the electrode's performance or the storage solution's integrity.

Apera Instruments 3M KCL Storage Solution bottle

Hình ảnh: A white plastic bottle containing Apera Instruments 3M KCL Storage Solution. The label on the bottle is primarily in German, indicating "Elektrolyt Lösung" (Electrolyte Solution) and "Kaliumchlorid 3mol/l" (Potassium Chloride 3mol/l), with a volume of "250 ml". The Apera Instruments logo is visible at the top of the label. The bottle has a black ribbed screw cap.

Hướng dẫn sử dụng

Routine Electrode Storage

To maintain optimal performance and extend the life of your pH or ORP electrode, it is highly recommended to store the electrode in Apera Instruments 3M KCL Storage Solution when not in use. This prevents the electrode's sensitive glass bulb and reference junction from drying out.

  1. Ensure the electrode is clean.
  2. Tháo nắp bảo vệ khỏi điện cực.
  3. Fill the electrode's storage cap or a small container with a sufficient amount of 3M KCL storage solution to fully immerse the electrode's sensing bulb and reference junction.
  4. Place the electrode into the solution, ensuring the sensing part is completely submerged.
  5. Secure the electrode in the solution to prevent spillage and evaporation.

Restoring Dry or Sluggish Electrodes

If your pH or ORP electrode has been stored dry, or if it exhibits sluggish response or unstable readings, its sensitivity and accuracy may be temporarily compromised. The 3M KCL storage solution can help restore its performance.

  1. Làm sạch điện cực thật kỹ.
  2. Immerse the electrode's sensing bulb and reference junction in Apera Instruments 3M KCL Storage Solution.
  3. Allow the electrode to soak in the solution for a minimum of 1 hour, or preferably overnight, to rehydrate the glass membrane and re-establish the reference junction potential.
  4. After soaking, rinse the electrode with distilled water and perform a calibration before use.

Maintenance and Storage of Solution

To ensure the longevity and effectiveness of your Apera Instruments 3M KCL Storage Solution, follow these guidelines:

Xử lý sự cố

This section addresses common issues related to electrode performance and how the storage solution can help.

Vấn đềNguyên nhân có thểGiải pháp
Electrode shows unstable readings or slow response.Electrode membrane is dry or dehydrated.Soak the electrode in Apera Instruments 3M KCL Storage Solution for at least 1 hour, or overnight. Ensure the sensing bulb is fully submerged.
Electrode requires frequent calibration.Improper storage leading to degradation of electrode performance.Always store the electrode in 3M KCL storage solution when not in use. If performance has degraded, try reconditioning by soaking.
Solution appears cloudy or contaminated.Exposure to contaminants or expired solution.Discard the contaminated or expired solution and replace with fresh Apera Instruments 3M KCL Storage Solution.

Thông số kỹ thuật

Thuộc tínhChi tiết
Tên sản phẩm3M KCL Storage Soaking Solution
Số hiệu mẫuAIX NUMX
Thương hiệunhạc cụ apera
Khối lượng mục8 Ounce chất lỏng (khoảng 236 ml)
KCL Concentration3M (3 mol/L)
Mẫu mụcChất lỏng
Thông tin gói hàngCái chai
Kích thước sản phẩm6.3 x 1.97 x 2.36 inch
Trọng lượng sản phẩm9 Ounce
Nước xuất xứHoa Kỳ

Thông tin bảo hành

Specific warranty details for the Apera Instruments 3M KCL Storage Soaking Solution are not provided in this manual. For comprehensive warranty information, please refer to the official Apera Instruments webtrang web hoặc liên hệ trực tiếp với bộ phận hỗ trợ khách hàng của họ.

Hỗ trợ và Liên hệ

For further assistance, technical support, or to download batch certificates for your solution, please visit the official Apera Instruments webđịa điểm:

www.aperinst.com

(Note: The image indicates a German website for certificates: aperainst.de/chargenzertifikate/. Please refer to your region's specific support channels.)

Tài liệu liên quan - AIX NUMX

Trướcview Máy đo pH cầm tay Apera SX811-SS để kiểm tra thực phẩm: Hướng dẫn sử dụng & Thông số kỹ thuật
Sách hướng dẫn sử dụng đầy đủ và thông số kỹ thuật của máy đo pH cầm tay Apera SX811-SS, được thiết kế để kiểm tra thực phẩm chính xác. Tìm hiểu về các tính năng, hiệu chuẩn, thiết lập, giao tiếp USB và xử lý sự cố.
Trướcview ORP60-Z Smart ORP/Redox Tester User Manual
User manual for the Apera Instruments ORP60-Z Smart ORP/Redox Tester, covering features, installation, operation, calibration, maintenance, technical specifications, and warranty. Includes detailed instructions and troubleshooting.
Trướcview Hướng dẫn sử dụng máy đo pH thông minh PH60Z-HT - Apera Instruments
Sách hướng dẫn sử dụng Máy đo pH thông minh Apera Instruments PH60Z-HT, trình bày chi tiết các tính năng, hoạt động, hiệu chuẩn, bảo trì và khắc phục sự cố đối với dung dịch có nhiệt độ cao và kiềm.
Trướcview PH60Z-PW Máy đo pH thông minh Bedienungsanleitung für reines Wasser
Umfassende Bedienungsanleitung für das Apera Instruments PH60Z-PW Máy đo pH thông minh. Erfahren Sie mehr über Kalibrierung, Messung, Wartung và technische Daten für präzise pH-Messungen in Reinem Wasser.
Trướcview Hướng dẫn sử dụng máy đo pH để bàn Apera PH700
Hướng dẫn toàn diện về vận hành, hiệu chuẩn và bảo trì máy đo pH để bàn Apera PH700. Tài liệu này bao gồm thông số kỹ thuật, mô tả thiết bị, quy trình đo pH và ORP, cài đặt thông số, chăm sóc điện cực và khắc phục sự cố.
Trướcview Apera Instruments SX731 Portable pH/Conductivity/ORP Meter User Manual
User manual for the Apera Instruments SX731 Portable pH/Conductivity/ORP Meter, covering its features, technical specifications, operation, calibration, maintenance, and warranty.