1. Giới thiệu
The SmartGen HAT560NB ATS Controller is an intelligent dual-supply module designed for Automatic Transfer Systems (ATS). It integrates digital, intelligent, and networked functionalities to provide precise voltage measurement and control for various power supply configurations. This controller is suitable for specialized ATS, Contactor ATS, and Air Break ATS applications, offering a compact structure, advanced circuitry, and high reliability.
It is engineered to reduce operational errors through automatic measurement and control, making it an ideal solution for managing power transfer between different sources like mains and generators.

Hình 1: Mặt trước view of the SmartGen HAT560NB ATS Controller, showing the LCD display and operational buttons.
2. Đặc điểm và tính năng
The HAT560NB controller incorporates a powerful microprocessor for accurate monitoring and control. Key features include:
- System type configuration: Mains (1#) & Generator (2#), Generator (1#) & Mains (2#), Mains (1#) & Mains (2#), Generator (1#) & Generator (2#).
- 132x64 LCD with backlight, offering optional Chinese and English display with push-button operation.
- Measurement and display of 2-way 3-phase voltage và tần số.
- Bảo vệ chống lại vol trên/thấptage, loss of phase, reverse phase sequence, and over/under frequency.
- Automatic and Manual operating modes. Manual mode allows forced switch closure or opening.
- All parameters are configurable on-site, secured by two different passwords for authorized access.
- Genset commissioning can be set to On-load or Off-load mode.
- Automatic re-closing function for the ATS Controller.
- Configurable closing output signal as either on intervals or continuous output.
- Applicable for ATS with one neutral position, two neutral positions, and non-position types.
- Monitors 1-3 phase AC mains voltagnghĩa là
- Manages changeover of both generator and mains contactors.
- Sends remote start commands to the generating set.
- Compatible with various contactors and changeover switch types.
3. Thiết lập và Cài đặt
Proper installation is crucial for the safe and reliable operation of the HAT560NB controller. Ensure all power is disconnected before beginning installation. Refer to the wiring diagrams and terminal descriptions for correct connections.
3.1 Sơ đồ đấu dây
The HAT560NB controller supports various wiring configurations depending on the ATS type. Below are typical wiring diagrams for different setups. Always consult a qualified electrician for installation.

Figure 2: Comprehensive wiring diagrams illustrating connections for ATYS3S, SGQ-N/T, SGQ-M, and VITZRO/PHETENG ATS controller types. These diagrams show connections for 1# and 2# power supplies, load, and remote start signals.

Figure 3: Additional wiring diagrams focusing on SGQ-N/T, SGQ-M, and Contactor ATS configurations, detailing input and output connections for the controller.
3.2 Connecting Terminals
The controller features clearly labeled terminals for power input, auxiliary outputs, and control signals. Ensure each wire is securely connected to its designated terminal.

Hình 4: Phía sau view of the HAT560NB controller, displaying the layout and labeling of all connecting terminals, including power inputs, auxiliary outputs, and communication ports.
4. Hướng dẫn vận hành
The HAT560NB controller offers both automatic and manual operation modes, accessible via its front panel buttons and LCD display.
4.1 Khởi động và hiển thị ban đầu
Upon powering on, the LCD will display system information, including voltage and frequency readings for both power sources. The backlight ensures visibility in various lighting conditions.
4.2 Lựa chọn chế độ
- Chế độ tự động: The controller automatically monitors the power sources and initiates transfer based on pre-set parameters and detected abnormalities (e.g., over/under voltage, frequency deviations, phase loss).
- Chế độ thủ công: Allows the user to manually control the opening or closing of the transfer switches. This mode is typically used for testing or specific operational requirements.
4.3 Cài đặt tham số
All operational parameters can be configured directly on the unit using the push-buttons and LCD interface. Access to parameter settings is protected by a two-level password system to prevent unauthorized changes. Refer to the detailed programming guide (not included in this manual) for specific parameter definitions and adjustment procedures.
5. Bảo trì
Regular maintenance ensures the longevity and reliable performance of your HAT560NB ATS Controller.
- Vệ sinh: Keep the controller's exterior clean and free from dust and debris. Use a soft, dry cloth. Avoid abrasive cleaners or solvents.
- Kiểm tra kết nối: Thường xuyên kiểm tra tất cả các mối nối dây điện để đảm bảo chúng chắc chắn và không bị ăn mòn. Các mối nối lỏng lẻo có thể dẫn đến hoạt động không ổn định hoặc lỗi hệ thống.
- Điều kiện môi trường: Đảm bảo môi trường hoạt động luôn nằm trong phạm vi nhiệt độ và độ ẩm quy định để tránh làm hư hỏng các linh kiện bên trong.
For any internal maintenance or repairs, contact qualified service personnel.
KHAI THÁC. Xử lý sự cố
This section provides guidance on common issues you might encounter with the HAT560NB controller.
| Vấn đề | Nguyên nhân có thể | Giải pháp |
|---|---|---|
| Bộ điều khiển không bật nguồn | No DC power supply; Incorrect wiring | Check DC 8.0V-35.0V power supply connections; Verify wiring according to diagrams. |
| ATS not transferring automatically | Automatic mode not selected; Fault detected on active power source (e.g., over/under voltage, frequency); Incorrect parameters | Ensure controller is in Automatic mode; Check power source status; Verify parameter settings. |
| Display shows error for voltage / tần số | Actual power source issue; Sensor/input wiring problem | Kiểm tra vol thực tếtage and frequency of the power source; Inspect AC voltage dây đầu vào. |
| Các nút không phản hồi | Temporary software glitch; Hardware issue | Restart the controller by cycling power; If issue persists, contact support. |
7. Thông số kỹ thuật
The following table details the technical specifications for the SmartGen HAT560NB ATS Controller.

Figure 5: Detailed specifications table for the HAT560N series ATS Controller, including operating voltage, power consumption, AC voltage input ranges, rated frequency, relay outputs, communication, dimensions, and environmental conditions.
| Mục | Đặc điểm kỹ thuật |
|---|---|
| Hoạt động Voltage | DC 8.0V-35.0V (continuous power supply) |
| điện áp xoay chiềutage Đầu vào | AC170V-270V (during AC power L1N1/L2N2 supply) |
| Tiêu thụ điện năng | <3W (Chế độ chờ: <2W) |
| Tần số định mức | 50/60Hz |
| Đóng đầu ra chuyển tiếp | 16A AC250V (Volts free output) |
| Đầu ra rơle phụ trợ 1 | 7A AC250V (Volts free output) |
| Đầu ra rơle phụ trợ 2 | 7A AC250V (Volts free output) |
| Đầu ra rơle phụ trợ 3 | 16A AC250V (Volts free output) |
| Đầu ra rơle phụ trợ 4 | 16A AC250V (Volts free output) |
| Đầu vào kỹ thuật số | GND connect is active |
| Giao tiếp | Giao diện LINK, Giao thức MODBUS |
| Kích thước vỏ hộp | 139mm x 120mm x 48mm (5.47 x 4.72 x 1.89 inch) |
| Bảng cắt | 130mm x 111mm |
| Điều kiện làm việc | Nhiệt độ: (-25~+70)°C, Độ ẩm: (20~93)%RH |
| Điều kiện lưu trữ | Nhiệt độ: (-25 ~ + 70) ° C |
| Mức độ bảo vệ | Vòng đệm IP55 |
| Cường độ cách điện | Áp dụng AC2.2kV voltage giữa vol caotagthiết bị đầu cuối e và âm lượng thấptagthiết bị đầu cuối điện tử; Dòng rò không quá 3mA trong vòng 1 phút. |
| Cân nặng | 0.62kg (1.63 pound) |