1. Giới thiệu

The Fluke TL175 TwistGuard Test Leads are designed for electrical measurement applications, offering enhanced safety and versatility. These test leads feature an adjustable tip shroud mechanism and a WearGuard lead wire wear indication system, ensuring reliable performance and user safety across various measurement environments. They are compatible with all instruments that accept standard 4mm shrouded banana plugs.

2. Thông tin an toàn

WARNING: To prevent possible electrical shock, fire, or personal injury:

  • Always use the test leads with the appropriate safety category rating for the measurement environment.
  • Inspect test leads for damage before each use. Do not use if insulation is damaged or if the inner contrasting color of the WearGuard system is exposed.
  • Ensure the test lead tips are fully inserted into the measurement device.
  • Không áp dụng nhiều hơn mức định mứctage, as marked on the test leads.
  • Keep fingers behind the finger guards on the probes during measurements.
  • Hãy cẩn thận khi làm việc với voltagđiện áp trên 30 V AC RMS, 42 V đỉnh hoặc 60 V DC. Các điện áp nàytagcó thể gây ra nguy cơ điện giật.

3. Tính năng sản phẩm

  • TwistGuard Extendable Tip Shroud: Patented design allows users to twist the probe handle to extend or retract the tip shroud, reducing tip exposure for higher safety categories (CAT III, CAT IV) and providing full tip exposure for lower categories (CAT II).
  • WearGuard Lead Wire Indication: Each test lead features two layers of silicone insulation. If the outer layer is nicked or scuffed, the inner contrasting color becomes visible, indicating the need for replacement.
  • Double Insulated Silicone Leads: Designed to withstand high temperatures and maintain flexibility in cold conditions.
  • Extra-Heavy Duty Strain Relief: Reinforced strain relief on both probe-end and plug-end for enhanced durability, tested beyond 30,000 bends.
  • Universal Input Plugs: Compatible with all instruments that accept standard 4mm shrouded banana plugs.
  • Removable 4mm Lantern Tips: Includes removable tips that thread onto the lead tip for versatile connections.
Fluke TL175 TwistGuard Test Leads

Hình 1: Hếtview of Fluke TL175 TwistGuard Test Leads, showing the red and black leads with their respective probe tips and banana plugs.

4. Thiết lập và Cài đặt

  1. Kiểm tra khách hàng tiềm năng: Before connecting, visually inspect both test leads for any signs of damage, cuts, or exposed inner insulation. If damage is found, replace the leads immediately.
  2. Kết nối với thiết bị: Insert the shrouded banana plugs (black for common, red for voltage/current) firmly into the corresponding input jacks of your multimeter or test instrument. Ensure a secure connection.
    Fluke TL175 Test Leads connected to a multimeter

    Figure 2: Fluke TL175 Test Leads properly connected to a digital multimeter.

  3. Adjust TwistGuard Shroud: The TwistGuard feature allows you to adjust the exposed tip length.
    • For CAT II measurements (e.g., wall outlets), twist the probe handle to fully expose the 19mm tip.
    • For CAT III or CAT IV measurements (e.g., circuit breaker panels, main service), twist the probe handle to retract the shroud, exposing only the 4mm tip for increased safety.
      Hand demonstrating the TwistGuard feature on a Fluke TL175 test lead

      Figure 3: A hand twisting the probe handle to adjust the TwistGuard tip shroud.

  4. Attach Lantern Tips (Optional): If your application requires a different connection type, the included 4mm lantern tips can be threaded onto the probe tips.

5. Hướng dẫn vận hành

Once properly connected and adjusted, the Fluke TL175 Test Leads function as standard test probes for your electrical measurements. Always refer to your multimeter's instruction manual for specific measurement procedures.

  • Tậptage Đo lường: Chọn vol thích hợptage range on your multimeter. Ensure the TwistGuard shroud is set for the correct safety category. Place the black probe on the common or ground point and the red probe on the point to be measured.
  • Đo lường hiện tại: For current measurements, ensure the red lead is connected to the correct current input jack on your multimeter (e.g., 10A or mA). The circuit must be broken to insert the meter in series.
  • Điện trở/Tính liên tục: Select the resistance or continuity function. The leads can be used to test circuit continuity or component resistance.
Fluke TL175 Test Lead being used to measure in a circuit breaker panel

Figure 4: Using a Fluke TL175 Test Lead in a circuit breaker panel, demonstrating a CAT IV application with the shroud retracted.

Fluke TL175 Test Leads being used to test an electrical outlet

Figure 5: Fluke TL175 Test Leads used to test an electrical outlet, suitable for CAT II applications with tips fully exposed.

6. Bảo trì

  • Vệ sinh: Clean the test leads with a damp vải và chất tẩy rửa nhẹ. Không sử dụng chất tẩy rửa mài mòn hoặc dung môi.
  • Điều tra: Regularly inspect the leads for any signs of wear or damage, especially the WearGuard insulation. If the inner contrasting color is exposed, the leads are compromised and should be replaced to maintain safety.
  • Kho: Store the test leads in a clean, dry environment, away from extreme temperatures and direct sunlight. Avoid sharp bends or kinks in the cables.

KHAI THÁC. Xử lý sự cố

  • Không đọc sách hoặc đọc sách không thường xuyên:
    • Ensure the banana plugs are fully inserted into the multimeter.
    • Check for visible damage to the lead insulation or connectors.
    • Perform a continuity test on the leads themselves by touching the tips together. If no continuity, the leads may be internally broken and require replacement.
  • Đọc không chính xác:
    • Verify the multimeter is set to the correct function and range.
    • Ensure the test lead tips are making good contact with the circuit points.
    • Check for corrosion or dirt on the probe tips or banana plugs.

8. Thông số kỹ thuật

Tính năngĐặc điểm kỹ thuật
Số hiệu mẫuTL175
Xếp hạng an toànCAT II 1000V, CAT III 1000V, CAT IV 600V, 10A maximum, Pollution Degree 2
Exposed Probe Tip Length19mm to 4mm (0.75" to 0.16") adjustable
Vật liệu dây chìDouble Insulated Silicone
Nhiệt độ hoạt động-20 đến 55 °C (-4 đến 131 °F)
Độ cao2000m (6,562')
Sự tuân thủEN61010-031
Kích thước sản phẩm10 x 3 x 2 inch
Trọng lượng sản phẩm120 gam (4.23 ounce)

Có gì trong hộp:

  • Fluke TL175 TwistGuard Test Leads (Red and Black)
  • Removable 4mm Lantern Tips

9. Bảo hành và Hỗ trợ

The Fluke TL175 TwistGuard Test Leads come with a 1-year warranty from the date of purchase, covering defects in materials and workmanship. For warranty claims, technical assistance, or further information, please contact Fluke Corporation customer support or visit the official Fluke webđịa điểm.

Nhà sản xuất: Tập đoàn Fluke

Ngày đầu tiên có sẵn: Ngày 1 tháng 2011 năm XNUMX

Tài liệu liên quan - TL175

Trướcview Đồng hồ vạn năng kỹ thuật số Fluke 179: Hướng dẫn bảo trì và dịch vụ tại hiện trường
Khám phá Đồng hồ vạn năng kỹ thuật số True-rms Fluke 179, được thiết kế để bảo trì điện và HVAC hiệu quả. Tìm hiểu về các tính năng, thông số kỹ thuật và phụ kiện được khuyến nghị cho dịch vụ hiện trường đáng tin cậy.
Trướcview Hướng dẫn sử dụng đồng hồ vạn năng kỹ thuật số Fluke 15B+/17B+/18B+
Comprehensive user manual for Fluke 15B+, 17B+, and 18B+ digital multimeters, covering features, operation, safety, maintenance, and specifications. This document provides detailed instructions for using the multimeters for various electrical measurements.
Trướcview Đồng hồ vạn năng kỹ thuật số cầm tay Fluke 106/107: Thông số kỹ thuật và tính năng
Thông số kỹ thuật chi tiết, điểm nổi bật của sản phẩm và thông tin chung về đồng hồ vạn năng kỹ thuật số cầm tay Fluke 106 và 107. Tìm hiểu về thông số kỹ thuật điện, độ chính xác, tính năng và các thiết bị đi kèm.
Trướcview Thông số kỹ thuật của đồng hồ vạn năng cầm tay kỹ thuật số Fluke 107 CAT III - Thông số kỹ thuật
Thông số kỹ thuật chi tiết, tính năng và thông tin chung về đồng hồ vạn năng kỹ thuật số cầm tay Fluke 107 CAT III. Bao gồm các phép đo điện, xếp hạng an toàn và chi tiết đặt hàng.
Trướcview Bộ chuyển đổi Fluke FEV100 cho trạm sạc xe điện: Dữ liệu kỹ thuật và thông số kỹ thuật
Khám phá thông số kỹ thuật, tính năng và quy trình kiểm tra của Bộ chuyển đổi Fluke FEV100, được thiết kế để kiểm tra an toàn và hiệu quả các trạm sạc xe điện (EVSE). Bao gồm thông tin an toàn, khả năng tương thích và chi tiết đặt hàng.
Trướcview Đồng hồ vạn năng Fluke 110 True-RMS: Thông số kỹ thuật và tính năng
Thông số kỹ thuật chi tiết và các tính năng của đồng hồ vạn năng True-RMS nhỏ gọn Fluke 110, được thiết kế để lắp đặt và khắc phục sự cố điện chính xác. Bao gồm độ chính xác, xếp hạng an toàn và các phụ kiện đi kèm.